Pang-industriya na UPS 5-7.5kVA

  • Pang-industriya na UPS 5-7.5kVA
  • Pang-industriya na UPS 5-7.5kVA
  • video
  • Evada
  • Tsina
  • XMI-D Serye
Ang XMI-D series na UPS ay partikular na idinisenyo para sa mga electrical power system, na makabuluhang nagpapahusay sa pagiging maaasahan ng power supply system. Ito ay ganap na nag-aalis ng epekto, surge, sags, at ingay na interference ng power grid. Sa pambihirang kalidad, mahusay na pagganap, at user-friendly na operasyon, nagbibigay ito ng berde at maaasahang proteksyon ng kuryente para sa mga naglo-load.
482 x 440x 264(6U)

  • 6U DC220V

  • 440 x 440 x 311


7U DC110V

Timbang ng rack-mount46 (panloob)46 (panloob)46 (panloob)85 (panloob)22 (panlabas)100 (panloob)
28/30 (panlabas)142 (panloob)28/30 (panlabas)145 (panloob)28/30 (panlabas)Ang produkto ay napapailalim sa aktwal na item. Ang mga detalye sa itaas ay maaaring magbago nang walang paunang abiso.8kVA10kVA
Input
Rated Voltage220Vac
Voltage RangePhase voltage (165 ~ 275) Vac
Frequency Range50 ± 5%)Hz
Rated DC Voltage110/220Vdc
Output
Rated VoltageSingle phase 220Vac
Voltage Accuracy(220 ± 1%)Vac
Output Frequency(50 ± 0.5%)Hz
Power Factor0.8
THDu<3% (linear full load), <5% (non-linear full load)
Overload Capacity105%~125%, switch to bypass in 10 min; 125%~150%, switch to bypass in 1 min;  >150%, immediately switch to bypass
Switching Time0ms
Current imbalance in parallel operation≤5%
Protection
OverloadSwitch to bypass power supply, automatically switch to mains power after load reduction
Overheat>85℃, switch to bypass power supply
Short CircuitInverter shutdown with protection alarm
FaultSwitch to bypass with protection alarm
UndervoltageAutomatic shutdown
Display
LED IndicationAC power indicator, inverter indicator, bypass indicator, DC undervoltage indicator, overload indicator, fault indicator
LCD DisplayAC input/output voltage, AC input/output frequency, DC input voltage, load precentage, apparent power, active power, output current, UPS operating status
Other Function
AlarmInput abnormality, low battery voltage, overload, and other error
CommunicationStandard RS-232/RS485 (supporting Modbus protocol), dry contact; SNMP remote monitoring (optional)
Environment
Operating Temperature(-5  40)℃
Relative Humidity0~95% (no condensation)
Noise<55dB @ 1 meter
Mechanical Indicators
Rack-mount with internal transformer
width x depth x height (mm)
422 x 461 x 1764U422 x 419
x 352(8U)
442 x 419
 x 442(10U
440 x 470 x 71216U
Rack-mount with external transformer
width x depth x height (mm)

482 x 440x 264(6U)482 x 440 x 2646U DC220V
440 x 440 x 311
7U DC110V
Rack-mount weight46 (internal)46 (internal)46 (internal)85 (internal)
22 (external)
100 (internal)
28/30 (external)
142 (internal)
28/30 (external)
145 (internal)
28/30 (external)
The product is subject to the actual item. The above specifications are subject to change without prior notice.



482 x 440 x 264

Kunin ang pinakabagong presyo? Sasagot kami sa lalong madaling panahon (sa loob ng 12 oras)